Your shopping cart is empty!
Free Delivery
7 day Replacement
1 Year Warranty
Top Brand
Secure transaction
Model No: IT189DWLCProduct: Fully Automatic Digital Water Level Controller with Sensor
Product OverviewThe IT189DWLC is a fully automatic water level controller designed to manage water pump operations based on the water levels in the overhead tank and underground sump. It ensures efficient water management with dry run protection, overload protection, and voltage fluctuation safeguards.
Package Contents 1x Water Level Controller Unit 6x Stainless Steel/Carbon Sensors 1x User Manual Sensor Connecting Wire (Optional, as per model)Features Suitable for single-phase motors (up to 2 HP) Works for both overhead & underground tanks Auto cut-off when tank is full Auto start when tank is low Dry run protection Overload protection Over/under voltage protection Digital display for live voltage and current Manual & automatic mode operation No need to press reset after errors (if timer is set)Working Description
1. Sensors Configuration 6 sensors total 3 for Overhead Tank → G1 (Low), B1 (High), R1 (Common) 3 for Underground Tank → G (Dry Run), B (High), R (Common) The common sensors (R & R1) go at the bottom of their respective tanks. G/G1 = Low level sensor (Motor ON) B/B1 = High level sensor (Motor OFF) G Sensor in Sump = Dry run detection Note: Distance between G and B in sump should not exceed 1 ft.2. Wiring Instructions Power Input: 230V AC (Phase & Neutral) to the input terminals Power Output: Connect motor’s phase & neutral to output terminals Sensor Wiring: Use 1 mm 3-core cable, ensure sensors are mounted steadily (not floating) ➕ Only Overhead Tank?If using only overhead tank: Short R, G, B sensors of the sump in the panel (link them using a wire) G and B LEDs will glow permanently, simulating full sump condition Controller Settings Auto Setting Mode Start motor in manual mode Press [SET] button for 3–5 seconds until "SET" appears Device auto-detects motor parameters (overload & dry run current) Manual Setting Mode Recommended only if auto setting fails or incorrectParameter Description Example
OC Overload Current – Set 30–40% above motor current If motor = 5A → Set OC ~ 7AUC Under Current (Dry Run) – Set 20–30% below motor current If motor = 5A → Set UC ~ 3.5AOV Over Voltage Cut-Off e.g., 280VUV Under Voltage Cut-Off e.g., 170VRST Error Reset Time (in minutes) e.g., 5 mins = Auto-reset after 5 mins Setting Procedure (Manual) Turn off motor Press [SET] once → OC appears Use [UP] / [DOWN] to set OC Press [START] → Next setting: UC Repeat for UC, OV, UV, RST After all settings, wait 3 seconds to auto-exit programming Technical SpecificationsPower Supply 230V AC, 50HzMotor Load Up to 2 HP (Single Phase)Sensor Type Carbon/Stainless/FloatDry Run Protection YesOverload Protection YesVoltage Protection Over & Under VoltageOutput Control RelayMounting Wall Mount Safety Instructions Ensure secure sensor mounting (no floating) Do not exceed motor capacity Use proper grounding and MCB for safety Ensure correct polarity while wiring Customer SupportImagine TechnologiesPhone: +91-8000066255Website: www.imaginetech.in