Model: IT880WLC
Package Contains:
Input Voltage: AC 230V
Output Voltage: AC 230V
Motor Capacity: Up to 2 HP
Control System: Overhead and Underground tank control with Dry Run Protection
Supported Sensors:
Stainless Steel Sensors
Carbon Sensors
Float Switch Sensors
Magnetic Sensors
Supported Starters:
Direct ON/OFF Switch
Monoblock Motor
Openwell Motor
Not Supported Starters:
Borewell Starter with Green & Red Push Buttons (Not supported for automatic motor starting)
AUTO Mode: Device operates automatically based on the selected working mode and tank levels.
MANUAL Mode: Motor starts when the Green Push Button is pressed. Pressing the Green Push Button again will stop the motor. (Manual control works regardless of selected mode)
(Underground Tank to Overhead Tank)
Works with both underground and overhead tanks.
Provides dry run protection.
Motor starts when:
Overhead tank is empty (G1 & B1 not in water)
Underground tank is full (G & B in water)
Motor stops when:
Overhead tank is full (G1 & B1 in water)
Motor will not start if underground tank is empty (dry run protection).
G sensor acts as dry run sensor.
Both G and B must be in water for motor to start.
Controls only the overhead tank.
No dry run protection in this mode.
Overhead tank is empty (G2 & B2 not in water)
User must start the motor manually using the Green Push Button.
Motor stops automatically when:
Overhead tank is full (B1 in water)
To restart the motor, press the Green Push Button again.
Functions exactly like Mode 1.
Additional buzzer alerts:
When Overhead tank is full (B1 in water): Buzzer sounds 40 fast beeps, then stops automatically. Can be stopped immediately by pressing Green Push Button.
When Underground tank is empty (G not in water): Buzzer sounds 40 slow beeps, then stops automatically. Can also be muted immediately by pressing Green Push Button.
To change the operating mode:
Press and hold the START/STOP Green Push Button for 6 seconds.
Buzzer will beep according to selected mode:
Mode 1 → 1 Beep
Mode 2 → 2 Beeps
Mode 3 → 3 Beeps
Mode 4 → 4 Beeps
Release the button after hearing the correct beep count.
R1 Sensor must be installed at the bottom of the overhead tank. Without R1, the device will not function.
Ensure all electrical and sensor connections are properly insulated and secure.
Use only the supported starter types and sensor configurations for best performance.